Chinese   Enlish  
  HomeCompanyTechnology Soalr ThermalApplicationSolar PVOEM Contact Us  
(1).Solar Collector
a. All glass horizontal solar collector
Features:
Reliable,efficient,Twin-Glass Vacuum tube
Easy plug-in installation anFeatures:
An economical solution
Could be either vertically or horizontally positioned
Especially suit large commercial or industrial applications, such as farm, restaurant, hotel, factory,etc.
frame : Imported color steel and aluminum-zinc plated steel, coated with hi-tech corrosion-resistant layer
MODEL Absorbing Absorbing Area
vacuum tube
(m2) diameter length tube
Sy- 1500/47-60 6.00 Φ 47mm 1500mm 60
Sy- 1800/58-50 7.14 Φ 58mm 1800mm 50

b. Heat Pipe Solar Collector
Structure and Principle: The heat pipe is hollow with the space inside evacuated, much the same as the solar tube.
Freeze Protection: Because the heat pipe is located within the evacuated glass tube, brief overnight temperatures as low as -20oC (14oF) will not cause the heat pipe to freeze.
⊙ High heat conduction coefficient:is 2000-5000 times of matal materials.
⊙ High quantity of heat conduction:is 1000times od metal materials.
⊙ Low temperature difference:less than 4℃ difference in 2 meter long pipe.

 

◆ Specifications:
Manifold casing material luminum
Frame material Aluminum
Header pipe material 1.2mm thickness Copper
Heat pipe material 0.7mm thickness Copper
Insulation Polyurethane 55mm or Rock wool
Rubber seals and rings UV stabilized high temperature silicon rubber
Test pressure 9 bar
Collector mounting Flat roof/inclined roof
Mounting angle 15℃-50℃
Inlet Outlet 3/4”


MODEL Ligthing
(m2)
Heat pipe Supply hot water(L/ ℃ ) 20/40" container
diameter ength No.
SY-1500/47-12 1.26 Φ47mm 1500mm 12 70/60 133/276
SY-1500/47-20 2.10 Φ47mm 1500mm 20 125/60 110/227
SY-1500/47-30 3.15 Φ47mm 1500mm 30 180/60 76/158

SY-1800/58-12
1.73 Φ58mm 1800mm 12 110/60 118/244
SY-1800/58-18 2.59 Φ58mm 1800mm 18 150/60 84/175

SY-1800/58-20
2.88 Φ58mm 1800mm 20 175/60 77/160
SY-1800/58-24 3.46 Φ58mm 1800mm 24 220/60 64/133
SY-1800/58-30 4.32 Φ58mm 1800mm 30 260/60 52/106

Features:
* Reliable, efficient, twin-glass solar tubes heat pipe
* Copper heat pipes for rapid heat transfer
 - Low maintenance effort
 - Easy installation of single or multiple units
* Corrosion resistant silver brazed copper header

NOTE:Absorber area is the part of the collector that actively absorbs the light rays. For solar tubes this is defined as the cross-sectional area of the inner tube (selective coated) measured using the outside diameter. (Eg. 0.047 x 1.72m = 0.08m2)
c.U Pipe Solar Collector
Liquid (pure water or glycol ) in the U pipe heats up, and the U pipe conducts thermal energy to the water inside the storage tank through internal copper coils.
As the water temperature can be adjusted using an automatic controller, user can get hot water all day long.

1. Outer glass 2. Vacuum 3. Selective coating 4,Aluminum heat transfer fin
5. U pipe(Hot terminal) 6.u pipe(cold terminal)
 
   
Model SY-150/58-12U SY-1800/58-12U
Type of Class Tube ф58 x 1500mm ф58 x 1800mm
Number of Tube 12 12
U Copper Type ф10 x 0.6mm ф10 x 0.6mm
Insulation Polyurethane or Rock wool
Fluid Type Glycol Solution
Fluid Content 2.75L 3.15L
Tested Pressure 12Bar 12Bar
System Pressure 6Bar 6Bar
Cut Lenth of efficiency ≥50% ≥50%
Ligthing Area(m2) 1.44 1.73 1.44 1.73
Absorb Area(m2) 0.82 0.99
Packing Demension 1760 x 1100 x 200mm 2060 x 1100 x 200mm
Gross Weight 50kg 60kg

(2).Solar Waer Heater
a. Thermosiphon Solar System
Thermosiphon systems move household water or a heat-transfer fluid through the system without pumps. The systems have the advantage that electricity outage and electric pump breakdown are not issues. This makes generally more reliable, easier to maintain, and possibly longer lasting than active systems. Thermosiphon systems are often less expensive than active systems, but are also generally less efficient due to slower water flow rates through the system

Feature: Stable, reliable, easy installation and scientific structure
Inner tank: SUS3042B Imported SUS3042B Food Grade Stainless Steel led by argon arc, superior water quality and drinkable
Outer shell: SUS3042B Stainless Steel, Imported color steel and aluminum-zinc plated steel, coated with hi-tech corrosion-resistant layer
Heat insulation layer: 50-60mm import polyurethane integral foaming, superior heat preservation

MODEL
Lighting
(m2)
vacuum tube Cubage
(L)
Qty.per20'/40Container
diameter length No.
410-1500/47-18-SYFR 1.89 Φ47mm 1500mm 18 100 60/116
410-1500/47-20-SYFR 2.10 Φ47mm 1500mm 20 111 56/108
410-1500/47-24-SYFR 2.52 Φ47mm 1500mm 24 133
47/91
410-1500/47-30-SYFR 3.15 Φ47mm 1500mm 30 166 34/65

MODEL
Lighting
(m2)
vacuum tube Cubage
(L)
Qty.per20'/40Container
diameter length No.
460-1800/58-18-SYFR 2.59 Φ58mm 1800mm 18 150 41/79
460-1800/58-20-SYFR 2.88 Φ58mm 1800mm 20 165 37/71
460-1800/58-24-SYFR 3.46 Φ58mm 1800mm 24 200
32/61
460-1800/58-30-SYFR 4.32 Φ58mm 1800mm 30 250 25/48

b. Closed-Loop Thermosiphon System
Thermosiphon solar collectors provides mains pressure pre-heating via a high efficiency copper coil heat exchanger located within the solar collector tank. The way in which the Mains Pressure solar collector heats water is the same as the Non pressure solar collector. Rather than using the water in the tank directly, as the Non pressure does, the type uses a 45 ~ 60m copper coil

Heat exchanger inside the tank which provides more than 1.5m 2 of heat transfer area. When wate Heat exchanger inside the tank which provides more than 1.5m 2 of heat transfer area. When water flows though the coil it absorbs heat from the water inside the solar collector tank. The solar collector tank is therefore a thermal store. For more details,please contact us with solarsking@hotmail.com

MODEL
Lighting
(m2)
vacuum tube Qty.per20'/40' Container
diameter length tube
SYS-C 470-1800/58-20 2.88 Φ58mm 1800mm 20 32/65
SYS-C 470-1800/58-24 3.46 Φ58mm 1800mm 24 30/62
SYS-C 470-1800/58-30 4.32 Φ58mm 1800mm 30 24/50

(3).Active-Loop Solar System
a.Open-Loop Solar Systems
An open loop system is for climates where there is no risk of freezing.Recirculation freeze protection can be provided by the Recirculation feature in the controller.An Open Loop Water Heating System provides many advantages It is the simplest and typically the least expensive active system to install. There is no heat exchanger, which allows efficient heat transfer directly to the water. The system Operates at standard line pressure. It is simple to add capacity to the system if demand changes. The system integrates easily with existing systems. When there is not enough energy for sun, an electrical back up element will be automatically switched on by controller.
MODEL
Cubage
(L)
Heat pipe Lighting
(m2)
contain
Diameter
(mm)
Length (mm) No.
Sy100
100 47 1500 20 2.22 Storage tank,controller,
collector,circular pump
Sy200 200 58 1800 20 3.00
Sy300 300 58 1800 30 4.29

b.Closed-Loop Solar System
Closed Loop Solar Heating Systems are suitable for single and multiple solar heating Application systems, e.g. domestic solar water heating, solar water heating hot tub, solar Swimming pool heating or solar space heating systems. The Closed Loop Solar Systems suitable for areas with questionable water quality and all climate conditions. The Closed Solar Heating Systems are the preferred option for extremely cold areas. When there is not enough energy for sun, an electrical or gas back up element will be automatically switched on by controller.

In this active, closed-loop system, incoming potable water is routed to the solar storage tank, but never into the collectors. A water and antifreeze mixture circulates from the collectors through a coil of pipe in the solar tank, and then is pumped back through the collectors. The potable water is warmed by heat transfer through contact with the pipe. In most climates, a 50/50 propylene glycol and water mixture will keep collectors from freezing. These systems require an expansion tank and a few other auxiliary components for filling, venting, and maintaining the system. A definite advantage to antifreeze systems is that the collectors can be mounted anywhere. These systems are pretty much the only choice in very cold climates.

MODEL
Cubage
(L)
Heat pipe Lighting
(m2)
contain
Diameter
(mm)
Length (mm) No.
Sy100c
100 47 1500 20 2.22 Copper coil Storage tank,work station,
collector,circular pump
Sy200 200 58 1800 20 3.00
Sy300 300 58 1800 30 4.29

For more information about Solar Water Heater design and installation,please contact with
solarsking@hotmail.com

(4).Solar System Accessories
a. Solar Work Station
Functions:
1) Intellectual mode
2) Function to heat regularly
3) Protective function in case power-off
4) Function to protect prevent frostbite
5) Function to display trouble
6) Water automatic cycle if the water temperature difference between tank and tube
   
b. Solar Controller
Main technical specifications
1. Power supply: AC220V±10%, power consumption :< 5W
2. Accuracy of tested temperature: ±2℃
3. Range of temperature to be tested:0~99℃
4. Power of controllable cycle pump :< 800W
5. Power of electric heater:≦3000W
6. Three inputs and two outputs
Main functions
1. Pump cycle function based on temperature difference
2. Preset electrical back up start time. (Three periods)
3. Freeze protection
4. over heat protection
5. Temperature display (Collector, Upper part of tank, Bottom part of tank)
6. Auto recovery and setting memory after power cut.
7. Trouble display
8. Clear LCD display
9. Second cycle pump control
 
 
FuJian Shengyuan Electrical Technology Co.,Ltd
网站设计:phpxwww.a-google.cn